Motor push finger do not start. Motor try to move and stop immediately. Servo-controller shows error „P03“.

P03 = positioning countering error

Possible causes:

  • Resolver on the backside of the bodytransport motor is damaged.
    • Check if the bearings are worn out!
  • Resolver is not fixed well on the shaft.
    • Fix it!
  • Wire break in the cable between resolver and servo controller.
    • Check the cable!

Back