Problem:

Circuit breaker Q5 trips when the machine is switched on or during production.

Possible Causes or Resolutions:

  • Measure voltages at all phases, even under load. It is possible that one phase did drop down, and this triggered the circuit breaker.
  • Measure the current of each phase with a current clamp after Q5. If the measured value is below the value of the circuit breaker and Q5 still keeps tripping, the circuit breaker may be defective. Replace it.
  • Maybe the parameter “Low bat voltage” (coming from Pacemaker) is set too low: That means that the contactor in the Pacemaker closes too early with a precharge voltage that is too low and therefore Q5 trips. To check this, please open a ticket to contact CanMan.

Problem:

All drives are starting correctly, but the vacuum and welding current are not active.

Possible Causes & Resolutions:

  • Welding pressure has been set below the min. value of 2.0 bar => Check the welding pressure setting value on the precise air-regulator and reset if needed.
  • Solenoid valve welding pressure Y10 does not work correctly  => Check the welding pressure valve Y10. Does the valve switch correctly and do the welding rollers close?
  • Welding rollers are closing and welding pressure is set correct, but no welding pressure value is displayed on the HMI => Check whether the analogue sensor B77 is working correctly or not.

 

 

 

 

Problem:

  • HMI communication error (see picture)
  • Not able to run the welder

IMG-20201111-WA0070.jpeg

 

Possible Causes & Resolution:

  • Turn the machine off and back on and see if the error message comes up again.
  • Check for the LED “on” at the PLC.
  • The machine isn’t showing any reaction (for example wire manual)
  • Please check the MPI-bus connection between the touch panel and the PLC.
  • Also check if all the PLC modules are properly mounted to the c-rail.
  • The machine was switched off for a longer period.
  • The PLC has an internal battery. To be sure that it can be sufficient charged, leave the machine power on for >24 hours.
  • Change the battery of the Pacemaker, see FAQ PM send error / PM receive error or welding parameter don’t match after starting the machine.