Problem:

Circuit breaker Q5 trips when the machine is switched on or during production.

Possible Causes or Resolutions:

  • Measure voltages at all phases, even under load. It is possible that one phase did drop down, and this triggered the circuit breaker.
  • Measure the current of each phase with a current clamp after Q5. If the measured value is below the value of the circuit breaker and Q5 still keeps tripping, the circuit breaker may be defective. Replace it.
  • Maybe the parameter “Low bat voltage” (coming from Pacemaker) is set too low: That means that the contactor in the Pacemaker closes too early with a precharge voltage that is too low and therefore Q5 trips. To check this, please open a ticket to contact CanMan.

Problem:

Machine stops and message „Pacemaker: Profibus communication error“ is displayed.

Possible Causes & Resolutions:

  • Cooling water valve: Wrong type of valve or plug without protective circuit (suppressor). The voltage peaks can cause interferences in the Pacemaker electronics. Always use the original plug and valve type.
  • Profibus plug: On the plug of first and last client of profibus system the termination resistant must be set to ON. Otherwise interference may occur.
  • Profibus cables: Check the position of the cables in the control unit. If they are close to contactors, high voltage peaks can create interferences.

Possible Causes & Resolutions:

  • No supply of a slave on the bus system.
    • Check supply of all slaves.
  • Address of slave on Profibus is wrongly adjusted.
    • Check the linmot controller. The correct setting you can find on the wiring diagram.
  • Wrong position of the switch for end resistant on the bus plug.
    • Check all switches on the complete bus system. Follow the cable seriously from PLC to last slave. First plug and plug of last slave must be set to ON, all other plugs to OFF.
  • Pacemaker™ settings lost because of empty ram battery
    • Replace battery. You can find more information here => Pacemaker – Support (canman.ch)
    • If the ram battery of the Pacemaker is empty and the settings are lost, the profibus communication may no longer start and also the analogue outputs, which control the speed for the wire drive and downstacker, are switched off (0Vdc).
    • After a battery change, the Pacemaker™ may have to be rebooted 3 – 4 times. To do this, disconnect Pacemaker™ from the mains and reconnect it (fuse breaker Q5 off and on again). Check the parameter settings before start the welding machine. If you have no access please open a ticket to get support => Can Man Support

 